Draft Specification

 

Model Draft Specification

  • Cut out and repoint the (Specify areas) removing the old mortar to a depth of (Specify Depth mm.)
  • Preparation and cutting out should be carried out in accordance with Method statement CC01 (standard brickwork and coursed stone) or SS01 (soft brickwork / stonework and irregular masonry joints) available from EasiPoint Marketing Limited.
  • Repointing should be carried out by gun injection using (select one of)
    • EasiPoint Standard dry blended, pre-packed gun injection mortar and installed strictly in accordance with EasiPoint method statement number SM02.
    • EasiPoint Historic dry blended pre-packed gun injection mortar and installed strictly in accordance with EasiPoint method statement number HM02.
    • EasiPoint Restoration dry packed gun injection mortar Grade and installed strictly in accordance with EasiPoint method statement number RM02.
    • EasiPoint Lime Putty Mortar and installed strictly in accordance with EasiPoint method statement number LPM02
    • EasiPoint Marine dry packed gun injection mortar and installed strictly in accordance with EasiPoint method statement number MAR02.
    • EasiPoint SR sulphate resistant dry packed gun injection mortar and installed strictly in accordance with EasiPoint method statement number SM02.
  • Curing and finishing to be in accordance with method statement EP03.

Contacts

Arthur McNiven

Arthur McNiven

Hard Landscaping Sector Specialist

01257 224900